    Wire Bonding Basics – Principles of Wirebond Technology for Semiconductor & QFN Packages

    1. Basic Principle of Wire BondingIn modern electronic manufacturing, wire bonding is the most widely used interconnection method. It relies on solid-state welding, which means that metals are bonded together without reaching their melting temperature. This process is especially critical in semiconductor packaging, including advanced formats such as QFN packages. 2. Four Fundamental Factors of…

    Read More Wire Bonding Basics – Principles of Wirebond Technology for Semiconductor & QFN PackagesContinue

  • Wire Bonder Equipment Maintenance

    Powernexx / ICONN / Rapid Wire Bonder Repair – Bonding Area Temperature Not Rising

    Model: Powernexx / ICONN / Rapid wire bonding machines – when the bonding area temperature fails to rise, the root cause is often a damaged heating rod. The machine will trigger the following error alarm in such cases.

    Read More Powernexx / ICONN / Rapid Wire Bonder Repair – Bonding Area Temperature Not RisingContinue

  • Wire Bonder Equipment Maintenance

    RPM process monitoring alarms

    RPM process monitoring alarms – generally, if the feature is not configured or enabled, and depending on the software version (as functions may vary slightly), the following alarms may occur.

    Read More RPM process monitoring alarmsContinue

  • Wire Bonder Equipment Maintenance

    Wire Bonder Repair Case – ERROR #1900 (ICONN PLUS)

    Root Causes & Analysis: Solution:Start with a simple reboot. If the issue repeats, proceed with cable re-check, cleaning, and software maintenance as outlined above.

    Read More Wire Bonder Repair Case – ERROR #1900 (ICONN PLUS)Continue

  • Wire Bonder Equipment Maintenance

    Wire Bonder Repair Case – ERROR #2233 Rail Unbias Motion Failed Solution

    Wire Bonder Repair Case – ERROR #2233 Error Description: Force system stepping alarm ERROR #2233 – Rail unbias motion failed.This error indicates an abnormal rail stepping motion, which prevents material bonding correction. Root Cause:The deviation between the MHS center point of the stepping material and the heating block center point was too large, resulting in…

    Read More Wire Bonder Repair Case – ERROR #2233 Rail Unbias Motion Failed SolutionContinue

  • Wire Bonder Equipment Maintenance

    Wire Bonder Repair Case – Troubleshooting ERROR #2279 Device Not Communicating

    Model: POWERNEXXFault Description: ERROR#2279 – Device Not Communicating The literal meaning indicates that the device status is not connected. From the fault description, it can be determined that the pneumatic board connection failed. After checking the hardware status, it was found that the air tube on the rear pneumatic board was loose, causing abnormal detection….

    Read More Wire Bonder Repair Case – Troubleshooting ERROR #2279 Device Not CommunicatingContinue

© 2025 If you need professional chip packaging services such as QFN packaging, please contact us on WeChat: 15634076956.